a:6:{s:1:"k";s:46:"categories-v1-760490727c9cbd3446100d37f4d347a3";s:1:"d";a:8:{i:0;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:8;s:14:"products_model";s:12:"9F-4IN7-HEFF";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:13:"0703062875561";s:13:"products_name";s:46:"Poultry Light Manager (JT-PLM) - Chicken Light";s:19:"products_extra_text";s:0:"";s:17:"products_quantity";i:10;s:16:"manufacturers_id";i:10;s:14:"products_image";s:9:"143_0.jpg";s:15:"products_weight";s:5:"0.560";s:26:"products_short_description";s:1320:"The Poultry Light Manager (JT-PLM) is an electronic device what was created to control lighting and temperature in poultry houses. The device is able to simulate sunrise and sunset. It is possible to connect dimmable 12V DC LED-lamps as well as dimmable fluorescent tubes with an electronic control gear (ECG) with a controller input voltage of 1 - 10 volts from JOSTechnik.
The Poultry Light Manger (JT-PLM) also gives the opportunity to operate an automatic heating if the inside temperature undershots an adjustable temperature threshold. The heating will be stopped again if the adjusted upper temperature treshold was reached.
As heating units infra-red lamps as well as normal electric heaters can be used. The power supply of these devices is based on 230 V AC. For that reason it is necessary to use the relay connection unit JT-Rel-HL.
An automatic ventilation is equally applicable. It can be used if the inside temperature exceeds an adjustable temperature threshold. The ventilation will be automatically switched off if the adjustable lower limit for ventilation was reached.
12 V–DC devices can be used as ventilation units as well as devices on 230 V-AC power. For connecting 230 V-AC devices the additional relay connection unit JT-Rel-HL has to be used.";s:20:"products_description";s:6103:"
is an electronic device what was created to control lighting and temperature in poultry houses. The device is able to simulate sunrise and sunset. It is possible to connect dimmable 12V DC LED-lamps as well as dimmable fluorescent tubes with an electronic control gear (ECG with a controller output voltage of 1-10 volts) from JOSTechnik.
The Light Manager (JT-PLM) automatically switches on the lighting in the poultry house at an adjustable time and starts to dim the light within a fixed given time from 0% to 100% (simulation of sunrise). As soon as an adjustable outside light sensor has detected the threshold of daylight, the artificial lighting will be automatically switched off. In case that the daylight has reached the default threshold before the dimmer start time (during summer) the dim process will not be started.
In the evening the light sensor initializes to turn on the artificial light in the hen house with a light level of 100%. In accordance with a predefined time the dim process starts at 100% and turns slowly down to 0% (simulation of sunset). Afterwards the lighting will be shut down completely. For that procedure the light controller will just take action if the outside light sensor indicates that the daylight comes below an adjustable threshold, that means during summertime the dim process will mostly not be started.
The Poultry Light Manager (JT-PLM) includes some more useful capabilities:
1. Automatic heating if the inside temperature undershots an adjustable temperature threshold. The heating will be stopped again if the adjusted upper temperature limit was reached.
As heating units infra-red lamps as well as normal electric heaters can be used. The power supply of these devices is based on 230 V AC. For that reason it is necessary to use the relay connection unit JT-Rel-HL.
2. Automatic ventilation if the inside temperature exceeds an adjustable temperature threshold. The ventilation will be automatically switched off if the adjustable lower temperature limit for ventilation was reached.
As ventilation units 12 V – devices as well as devices on 230 V AC power can be used. For connecting 230 V – devices the additional relay connection unit JT-Rel-HL has to be used.
Connecting terminals of the device
The Light Manger unit (JT-PLM) has following terminal connections:
1. Connection for a separate 12 V DC wall plug transformer, the connection of a 12 V solar power supply is also possible. An integrated polarity protection prevents the device from damage by voltage reversal. The operation of the device with common batteries like AA or AAA a.s.o. is not possible.
2. Connection for an additional external light sensor (an essential sensor to be used inside of the shed if the controller unit is fixed outside of the shed)
3. Connection for an additional external temperature sensor (an essential sensor to be used inside of the shed if the controller unit is fixed outside of the shed). The additional sensor mentioned under point 2. and 3. are not necessary if the controller is mounted inside the shed.
4. Connection for LED lamps
5. Connection for T5 - fluorescent tubes (it means connection for the switching voltage, connection for auxiliary relays)
6. Connection for heater (it means connection for an auxiliary relay)
7. Connection for Ventilator (it means connection for an auxiliary relay)
The Light Manager itself uses just a low voltage of 12 V AC. So it is safe for the costumer to make some connections himself.
The connections of 230 V – devices to the additional relay units like JT-Rel-HS and JT-Rel-LS have only to be made by qualified professionals.
Installation of the device
The controller device (JT-PLM) can be fixed outside of the poultry house (IP 65) as well as inside. The wall plug transformer is just applicable for inside use.
Handling of the device
The operation of the light controller (JT-PLM) is easy done. It is just necessary to adjust the desired parameters. That can be done by using the setup menu. All adjustable values will be shown on the display. It is not necessary to open the device to do these adjustments. The descriptions of the operations are given in the operating manual.
The display shows following adjustable conditions and values (dependent on context):
1. Current time of the day.
Switching time for artificial sunrise
Switching time for “light off” in the evening
2. Temperature outside*
temperature inside*
3. Brightness outside*
Brightness inside*
4. External devices **
Heater ON/OFF
Ventilator ON/OFF
5. Light controller
“Sunrise”
“Sunset”
In addition to the display a permanent status indication is given by LEDs which are mounted on the motherboard of the controller and are visible through the lid of the transparent casing. Following conditions are indicated by the LEDs:
1. Dimming or lighting ON/OFF
2. Heater ON/OFF
3. Ventilator ON/OFF
The integrated digital clock is battery-backed, includes an automatic switch-over between standard time and daylight saving time and continues to run in fact of a power interruption (only the internal clock, not the time display). The input data are saved in the system and will be restored after a power cut. Then the power is back, the device will reinitialize and will load again the user defined data sets. A new setup is not necessary.
* Device is outside mounted or an additional remote temperature sensor is connected (to order extra).
** External devices will be connected via a separate power module (to order extra). A 230 V-AC power connection is required to operate external devices.
Poultry Light Manager dimensions: 120 x 120 x 55 mm
is required as an optional accessory for the gate control unit "Poultry Door Opener" (JT-PDO), JT-HK , KS-SFH, Poultry House Butler PHB and Poultry Light Manager ( PLM ) if it is placed indoors. Thereby, the SFH outdoor light sensor is installed outside of the building and connected inside to the gate control unit (JT-PDO, KS-SFH, JT-HK) using the control cable.
Individual cable length are available!
for light control PLM, PHB2 and PHB2-R... from JOSTechnik!
This 230 V LED tube with bracket can be dimmed without flickering with light controls from JOS Technik. Up to 10 dimmable light strips can be connected via the REL-LS-HL connection module.
If LED components are operated directly with a perfectly smoothed DC voltage (DC voltage without significant ripple noise), these LED lamps also show a flicker value that is negligible in practice and are therefore considered to be flicker-free per se.
Attention: Connection only possible via additional connection module REL-LS-HL!
Connecting the cables:
---------------------------------------
Brown cable -> 230V L
Blue cable -> 230V N
Gray cable -> DIMM +
Black cable -> DIMM -
---------------------------------------
Technical data
Supply voltage 230 V
Energy efficiency class E
Base light bar with mounting clips power cord
Rated power consumption 12 W
Luminous flux 1430
Lumens per watt 124.4 lm/W
Beam angle 120
Color temperature 3000 Kelvin - warm white
Color rendering index >80
Dimmable yes
Rated life 50,000 hours
number of switching cycles
Dimensions length 600 mm
ignition time
Residual brightness at end of life
temperature range
Weighted self-consumption
light output
Seconds to reach 60% of full luminous flux
Degree of protection IP65
Mercury content 0.0mg
Rated peak luminous intensity in candelas
Information on disposal:
Lamps with the WEEE mark can be returned to special collection points.
or light controller from JOSTechnik and 6V-DC lighting systems!
If LED-lamps are straight connected to a DC-voltage without significant ripple noise, these lamps will show an unattended flickering and so they are rated as flicker-free.
Technical data:
Supply voltage 6 V DC
Energy efficiency class F
Base Light strip with mounting clips
Nominal power consumption 3 W
Luminous flux 270 in sphere (360°)
Lumens per watt ≥ 90 lm/W
Beam angle 120°
Colour temperature 2800 - 3200 Kelvin - warm white
Colour rendering index >81 RA
Rated service life 50,000 hours
Number of switching cycles ≥ 10,000
Dimensions (L x W x H) 280 mm x 18 mm x 12 mm
Ignition time >0.3 s
Residual brightness at end of service life 15%
Operating temperature range -20°C - +40°C
Weighted own consumption 6 kWh / 1000 h
Luminous efficacy ≥ 96%
Seconds to reach 60% of full luminous flux > 0.58 s
Protection rating IP65
Mercury content 0.0 mg
Rated peak luminous intensity in candela 600 cd
Proper disposal:
Lamps labelled with the WEEE symbol can be returned to suitable collection centres.
Attention: Only suitable for 12 V DC !!!
";s:20:"products_description";s:2052:"for light control PLM and PLMmini from JOSTechnik and 12V light systems!
Attention: Only suitable for 12 V DC !!!
This 12 V DC LED lamp as a light bar with bracket can be dimmed without flickering with light controls from JOS Technik. Up to 3 dimmable 12W light strips can be connected directly without a relay module.
If LED components are operated directly with a perfectly smoothed DC voltage (DC voltage without significant ripple noise), these LED lamps also show a flicker value that is negligible in practice and are therefore considered flicker-free.
Technical dataSupply voltage 12 V DC
Energy efficiency category F
Socket strip light with mounting clips
Power consumption 12 W
Light flux 1 050 in Sphere (360°)
Lumen per Watt ≥ 90 lm / W
Beam angle 120°
Colour temperature 2800 - 3200 Kelvin - warm white
Colour rendering index > 81 RA
Dimmable yes
Average light bulb lifespan 50.000 hours
Average amount of switching cycles > 10.000
Dimensions (L x W x H) 340mm x 18mm x 12mm
Ignition time >0,3 s
Intensity at the end of lifespan 15 %
Temperature range -20°C - +40°C
Weighted power consumption 12,0 kWh / 1000 h
Luminous efficiency ≥ 96%
Seconds until 60% of full light flux is reached 0,58 s
Protection class IP 65
Mercury content 0,0 mg
Max. light intensity (candela) 600 cd
Proper disposal:
Lamps labelled with the WEEE symbol can be returned to suitable collection centres.
for light control of JOS Technik 12V flap actuators and for 12V lighting systems!
Attention: Only suitable for 12 V DC !!!
This 12 V DC LED lamp as a light bar with bracket can be dimmed without flickering with light controls from JOS Technik. Up to 5 dimmable 6W light strips can be connected directly without a relay module.
If LED components are operated directly with a perfectly smoothed DC voltage (DC voltage without significant ripple noise), these LED lamps also show a flicker value that is negligible in practice and are therefore considered flicker-free.
Technical dataSupply voltage 12 V DC
Energy efficiency category F
Socket strip light with mounting clips
Power consumption 6 W
Light flux 554 in Sphere (360°)
Lumen per Watt ≥ 90-100 lm / W
Beam angle 120°
Colour temperature 2800 - 3200 Kelvin - warm white
Colour rendering index > 81 RA
Dimmable yes
Average light bulb lifespan 50.000 hours
Average amount of switching cycles > 10.000
Dimensions (L x W x H) 340mm x 18mm x 12mm
Ignition time >0,3 s
Intensity at the end of lifespan 15 %
Temperature range -20°C - +40°C
Weighted power consumption 6,0 kWh / 1000 h
Luminous efficiency ≥ 96%
Seconds until 60% of full light flux is reached 0,58 s
Protection class IP 65
Mercury content 0,0 mg
Max. light intensity (candela) 600 cd
Proper disposal:
Lamps labelled with the WEEE symbol can be returned to suitable collection centres.
for connecting heaters or ventilators with 230 V operating voltage !
The “Poultry Light Manager” supplies a 12 V control voltage for that module, so it it possible to connect and switch devices with 230 V operating voltage and a power consumption of max. 2000 W (like heaters or ventilators).
!!! Please note: The connection of 230-Volt-devices like heaters, ventilators, lamps and fluorescent tubes have only to be done by qualified professionals.